DME 7.8 DME 7.80 274 Overrun Recirculating Air Valve Output Stage - Below Limit Diagnosis conditions • Engine running • Battery positive voltage greater than 7 V Possible fault cause ♦Short to ground triggering wire Affected terminals III/16 Diagnosis/Troubleshooting Note! The wiring for the overrun recirculating air valve is routed via the connector X 59/3 pin 8. Work instruction Display OK If not OK 1 Check triggering wire for ♦Connect special tool 9637 to ∞ Ω Repair wiring har- short to ground. wiring harness (DME control ness. module plug). ♦Remove plug connection of overrun recirculating air valve. ♦Measure resistance between III/ 16 and ground. 274 Overrun Recirculating Air Valve Output Stage - Above Limit Diagnosis conditions • Engine running • Battery voltage greater than 7 V Possible fault cause ♦Short circuit to B+ triggering wire Affected terminals III/16 0-198 page 2 2138 P1657 p1657 Printed in Germany – 3, 2001