Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 1105
DME 7.8 DME 7.8 0 · 0-199P1671
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.8 0
0-199P1671
DME relay/control module faulty (computer monitor-
ing: reset) – signal implausible
Diagnosis conditions
• Ignition on
Possible fault cause
♦Undervoltage
♦DME relay faulty
♦DME control module faulty
This fault may be entered if the control module has been operated
with undervoltage.
Affected terminals
I/1 and I/8
Diagnosis/troubleshooting
Note!
If no fault is present, erase the fault memory.
Work instruction Display OK If not OK
1 Check voltage supply, ter- ♦Measure voltage between pin I/ > 11 V
minal 15 1 and ground.
2 Check DME relay ♦Switch on the ignition Battery positive volt- Check triggering of
♦Measure voltage between pin I/ age DME relay
Replace DME relay 18 and ground
3 Replace DME control module. Step 4
4 Perform adaptation. ♦Switch on the ignition → End → End
♦Wait one minute
♦Do not press the accelerator
♦Switch off the ignition for at
least 10 seconds
♦Read out the fault memory
2470 P1671 0-199 page 1
Printed in Germany – 8, 2002 p1671
This is a source reference. Confirm exact model applicability in the original material.