Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 1113
DME 7.8 DME 7.8 0 · 0-201.1P1676
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.8 0
0-201.1P1676
Engine Compartment Purge Fan Output Stage – Above
Limit
Diagnosis conditions
• Engine running
• Battery positive voltage greater than 7 V
• Engine compartment purge fan switched on once
• Engine compartment temperature greater than 75 °C
• Front and rear lids closed
Note!
The triggering wire for relay terminal 85 is monitored.
The rear lid may be opened to speed up the warming process. In
order to proceed with the diagnosis, the rear lid must then be
closed.
Possible fault cause
♦Short circuit to B+
♦Relay faulty
♦DME control module faulty
Affected terminals
Terminal II/20
Diagnosis/Troubleshooting
Work instruction Display OK If not OK
1 Check relays. ♦Remove relay Approx. 75 Ω Replace relay
Step 2 → End ♦Measure resistance between Pin
85 and Pin 86
2 Check wiring from DME ♦Connect special tool 9637 to 0 V Repair wiring har-
control module to relay wiring harness (DME control Step 3 ness
for short circuit to B+ module plug). → End.
♦Remove relay
♦Measure voltage between spe-
cial tool 9637 plug II Pin 20 and
ground
♦Switch on the ignition.
1981 P1676 0-201.1 page 1
Printed in Germany – 6, 2002 p1676