DME 7.8 DME 7.8 0 · 0-201.7P2096

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 1129
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.8 0 0-201.7P2096 Signal Delay Time for Oxygen Sensor Ageing - Above Limit Diagnosis conditions • Oxygen sensing after TWC is active • No secondary air • No diagnosis of secondary air system • EVAP canister not highly loaded • No faults in memory Possible fault cause ♦Oxygen sensor Affected terminals - Diagnosis/Troubleshooting Note! Do not use contact spray on the connectors to oxygen sensor. Work instruction Display OK If not OK 1 Read out regulator delay Less than 1.2 sec- Replace oxygen after TWC, bank 1, using onds sensor PST 2 or a scan tool Note! Do not confuse oxygen sensor ahead of catalytic converter and oxy- gen sensor after catalytic converter. 2469 P2096 0-201.7 page 1 Printed in Germany – 7, 2002 p2096