Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 1133
DME 7.8 DME 7.8 0 · 0-201.9P2098
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.8 0
0-201.9P2098
Signal Delay Time for Oxygen Sensor Ageing, Bank 2 –
Above Limit
Diagnosis conditions
• Oxygen sensing after TWC is active
• No secondary air
• No diagnosis of secondary air system
• EVAP canister not highly loaded
• No faults in memory
Possible fault cause
♦Oxygen sensor
Affected terminals
-
Diagnosis/Troubleshooting
Note!
Do not use contact spray on the connectors to oxygen sensor.
Work instruction Display OK If not OK
1 Read out regulator delay Less than 1.2 sec- Replace oxygen
after TWC, bank 2, using onds sensor
PST 2 or a scan tool
Note!
Do not confuse oxygen sensor ahead of catalytic converter and oxy-
gen sensor after catalytic converter.
2469 P2098 0-201.9 page 1
Printed in Germany – 7, 2002 p2098