fullymatted.
Back to search
Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 1135

DME 7.8 DME 7.8 0 · 0-201.10P2099

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 1135
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.8 0 0-201.10P2099 Signal Delay Time for Oxygen Sensor Ageing, Bank 2 Below Limit Diagnosis conditions • Oxygen sensing after TWC is active • No secondary air • No diagnosis of secondary air system • EVAP canister not highly loaded • No faults in memory Possible fault cause ♦Oxygen sensor Affected terminals - Diagnosis/Troubleshooting Note! Do not use contact spray on the connectors to oxygen sensor. Work instruction Display OK If not OK 1 Read out regulator delay more than 1.2 sec- Replace oxygen after TWC, bank 2, using onds sensor PST 2 or a scan tool Note! Do not confuse oxygen sensor ahead of catalytic converter and oxy- gen sensor after catalytic converter. 2469 P2099 0-201.10 page 1 Printed in Germany – 7, 2002 p2099

This is a source reference. Confirm exact model applicability in the original material.