fullymatted.
Back to search
Workshop Manuals

Diagnosis of Oxygen Sensing System Mixture Adaptation|Page 2508

Add to repair workspace
Open repair workspace
Original source
Page 1 Oxygen Sensor: Testing and Inspection OXYGEN SENSOR MONITORING General Description The response rate of the upstream oxygen sensor is monitored by measuring the period of the lambda control oscillations. This measurement is performed under the following conditions. manual transmission automatic transmission engine speed: 1,400 - 2,600 rpm and 1,200 - 2,200 rpm load: 0.7 [<] IL [<] 1.9 ms and 0.7 [<] TL [<]2.2 ms (catalyst temperature is[>] 352 °C) Monitoring Structure Oxygen Sensor Monitoring Monitoring of electrical faults of sensors upstream and downstream of catalyst: Implausible voltages - ADC-voltages exceeding the maximum threshold UMAX are caused by a short circuit to Ubat - ADC-voltages falling below the minimum threshold UMIN are caused by short circuit of sensor signal or sensor ground to EMC ground Implausible course of sensor voltage A open circuit of the sensor upstream catalyst can be detected, if the ADC-voltage remains in a specified range after the sensor has been heated. Flow chart of monitoring function (oxygen sensor)