Air Injection Control Valve|Service and Repair|Page 2857

Add to repair workspace
Open repair workspace
Original source
Page 5 5. Press together the plug connection on top and bottom of the central intake distributor -3- and pull out the pipe. 6. Disengage switch-over valve of the tank ventilation -4- from the plastic clip and pull off cable plug. 7. Remove coolant bleeder hose -arrow- by undoing the spring-band clamp and then pulling off the hose. Collect any draining water. 8. Remove central intake distributor by undoing all four screw-type hose clamps -2- and then pressing the rubber sleeves on the left and right off the central intake distributor with a suitable tool. Remove central intake distributor. 9. Remove the vacuum lines from both rubber sleeves and remove the rubber sleeves with the screw-type hose clamps. 10. In vehicles with air conditioning, the following work operations must be performed: a. Remove the drive belt from the belt pulley of the air-conditioning compressor. Mark the running direction of the belt with a coloured pen. Slacken belt by turning the tensioning pulley (a/f 24) clockwise, hold still and simultaneously take the drive belt off the belt pulley of the

This is a source reference. Confirm exact model applicability in the original material.