Page 6
air-conditioning compressor. Carefully allow the tensioning roller to turn back into tensioning position.
b. Disconnect battery positive lead
-1-
at B+ disconnection point. Unscrew the hexagon nut M8 and remove the positive lead. Then unscrew the
hexagon-head bolt M6 x 12
-2-
at the holder and lay the holder and box to one side.
c. Extract Pentosin fluid from the servo-tank with a pump. Dispose of extracted Pentosin according to the relevant regulations. Lay a cloth under
the tank to collect any emerging Pentosin. Open the bayonet lock anti-clockwise and remove the tank. Immediately seal the lower tank opening
with a plug (
dia. approx. 30 mm
).
NOTE:
After removal, place the air-conditioning compressor on a suitable protective support (e.g. foam, neoprene).
d. Remove the air-conditioning compressor. Tool recommendation:
1/4 inch
-Figure d3-
. 3 hexagon-head bolts M8: Unscrew 2 bolts at rear
-1-
, 1 at front
-2-
. For better access to the front threaded part
-2-
, remove the engine compartment temperature sensor with the rubber sleeve at the
right intake distributor.
Front threaded part, air-conditioning compressor