Page 7
Figure d3: recommended 1/4 inch tool for the front compressor screw
e. Lift out air-conditioning compressor with connected leads. To do so, pull up the front fastening screw in the aluminium spacer sleeve and hold
it tight. Disconnect the ground cable from the plug connection and lay it to one side on a protective support. Also secure against falling down
(tie wraps).
11. Remove hose from the secondary pump
-4-
.
12. Remove generator.
13. Remove the cable plug of the knock sensor (cylinder bank 1 - 3)
-1-
and unscrew the M8 hexagon-head bolt of the knock sensor
-2-
; then remove
the knock sensor. Unscrew the air line union nut (hexagon a/f 22)
-3-
on the distributor housing.