Page 1 Expansion Valve: Service and Repair Removal 1. Remove the cover above the heating/air-conditioning system. 2. Remove the refrigerant by suction using the service unit. 3. Detach the air-conditioning lines at the expansion valve. Immediately close connections and lines with plugs so that they are air-tight. 4. Undo the expansion valve and remove it. Immediately close the lines to the evaporator with plugs so that they are air-tight. Installation 1. Do not remove plugs until shortly before installation. Replace O-rings and wet the new rings with refrigerant oil. 2. Refrigerant oil removed from a previously run air-conditioning system may no longer be used (special-category waste). Tightening torques: Screw M5 6 Nm (4.5 ftlb) Screw M6 9 Nm (6.5 ftlb)