fullymatted.
Back to search
Workshop Manuals

Discharge Air Temperature Sensor / Switch, HVAC|Service and Repair

Add to repair workspace
Open repair workspace
Original source
Page 1 Discharge Air Temperature Sensor / Switch: Service and Repair Removal 1. Remove footwell bulkhead. Unclip center console cover at the front and remove the toot- well vent (3 screws). 2. Turn blower outlet sensor by 90 ° and pull it out. 3. Pull electrical plug connection off blower outlet sensor. Installation 1. Position temperature sensor on the heating/air-conditioning unit housing and turn by 90 ° (tighten). 2. Engage electrical plug connection and route wire carefully.

This is a source reference. Confirm exact model applicability in the original material.