Instrument Cluster Diagnosis - System K22, K23, K27|Page 5344

Add to repair workspace
Open repair workspace
Original source
Page 20 The tuner is part of the PCM2 (on the main board). Voice Control System (VOCS (Optional)) Voice Control System (VOCS (optional)) The VOCS (optional) is designed as a module box which can be pushed into the PCM2 (optional). Once inserted, an electronic switch is opened and the module is integrated into the MOST ring. Wake-Up Function Wake-up Function All control modules connected to the MOST are in sleep mode if the PCM2 is deactivated. When the PCM2 is switched on, a 'light' is switched on via the MMI It is reinforced and passed on by the MOST control modules that are connected. Country-Specific Tuner Settings Country-specific tuner settings The following country-specific tuner settings can be coded: - Asia. - Australia. - Europe. - Japan. - North America. - South Africa. - South America. General Information on the Fault Memory General information on the fault memory Fault code setting conditions Fault codes can be set in several circumstances, e.g.: - When disconnecting battery. - Plug connections disconnected. - Power failure. In these circumstances, no fault is present in the system and the fault memory must be erased. Fault memory Info key [F8] In order to be able to assess the fault exactly, the fault memory Info key [F8] must be pressed. This information should be saved using the Save key [F4] and printed out. If a fault code is stored with "not present" status and no other problems are present, then the fault memory must be erased. Fault type - Frequency counter/Temperature/Voltage; Speed/Time of occurrence. Supply voltage fault type The display shows which fault type has occurred: - Undervoltage '[<]  9 V'. - Overvoltage '[>] 16 V'. Frequency counter When a fault first occurs, a fault entry with the status 'present' is set in the fault memory and the counter is simultaneously set to '50'. If a fault is present, the counter is incremented by one whenever the system is 'booted'. The maximum count is 255. The counter is decremented if the status 'fault no longer present' is entered and the fault does not occur again when the system is 'booted'. The entry in the fault memory is erased automatically when the counter reaches 0. If the error occurs again when the counter is between 1 and 49, the counter is reset to 50. Temperature: The value indicates the temperature (temperature sensor in the gateway) at the time the fault occurred. The temperature of the fibre optic transmitter is monitored: max 85°C. Voltage The value indicates the voltage at the time the fault occurred. Vehicle speed: The value indicates the vehicle speed at the time the fault occurred.

This is a source reference. Confirm exact model applicability in the original material.