fullymatted.
Back to search
Workshop Manuals

Component Tests and General Diagnostics|Page 5380

Add to repair workspace
Open repair workspace
Original source
Page 16 - Treble - maximum value - Volume - maximum value - Volume - minimum value - Volume - centre position NOTE: The activated drive link is automatically switched off after approximately 20 seconds . PCM2 Control Module (Head Unit) The PCM2 control module (head unit) includes the following components: Internal: PCM2 gateway PCM2 Man Machine Interface (MMI) Internal amplifier (optional, depending on the equipment) Tuner Single CD Navigation (optional/insertion) VOCS (voice control system) (optional/insertion) Wake-up and distribution line diagnosis control Controller Area Network (CAN) Comfort MOST switch External: External amplifier (optional, Harman or BOSE) CD changer (CDC), (optional) Telephone/telematics (optional) The PCM2 consists of at least two but a maximum of four MOST nodes, (Gateway, MMI and Navigation and VOCS (optional)), which communicate with each other electronically via the MOST. Data is transferred outside of the PCM2 via the optical MOST. Telephone/Telematics The telephone/telematics feature is available as an option and is linked to the PCM2 via the optical waveguide. Tuner The tuner is part of the PCM2 (on the main board). Unlock Counter Interruptions occur in the system if perfect communication is no longer possible. If the relevant threshold values are exceeded, an entry is recorded in the appropriate control module and the "unlock counter" is incremented. External Amplifier The external amplifier (Harman or BOSE) is available as an optional feature and is linked to the PCM2 via the optical waveguide. Internal Amplifier The internal amplifier is part of the PCM2 (installed on the main board). Wake-up Function All control units connected to the MOST are in sleep mode if the PCM2 is deactivated. When the PCM2 is switched on, a "wake-up signal" is sent via the MMI. This signal is answered by the MOST control modules that are connected via the optical MOST. The check-back signals are stored as a MOST actual installed components list by the MMI and are compared with the MOST required installed components list. If a control unit is not detected, this will be reported to the gateway and stored. The MOST switch will then close and control units connected to the optical MOST will be switched off again. If the MOST actual installed components list matches the MOST required installed components list and the checkbacks occur within 40 ms , communication will be established with all control units. The MOST switch will now be held open. PCM2 MMI - Introduction

This is a source reference. Confirm exact model applicability in the original material.