Page 29 The telephone/telematics feature (optional) is available as an option and is linked to the PCM2 via the optical waveguide. Terminating Resistors In The CAN Terminating Resistors In The CAN Terminating resistors are fitted to each end of the wiring to prevent reflection on the wiring. These terminating resistors are integrated into each control module. The interconnection prevents the resistors from being measured with the ohmmeter from the outside. Tuner Tuner The tuner is part of the PCM2 (on the main board). Voice Control System (VOCS) (Optional) Voice Control System (VOCS) (optional) The VOCS (optional) is designed as a module box which can be pushed into the PCM2 (optional). After the insertion, an electronic switch is opened and the module is integrated into the MOST ring. Wake-Up Function Wake-up Function All control modules connected to the MOST are in sleep mode if the PCM2 is deactivated. When the PCM2 is switched on, a 'light' is switched on via the MMI It is reinforced and passed on by the MOST control modules that are connected. Country-Specific Tuner Settings Country-specific tuner settings The following country-specific tuner settings can be coded: - Europe - North America - South America - Australia - Asia - South Africa - Japan General Information on the Fault Memory General information on the fault memory Fault code setting conditions. Fault codes can be set in several Circumstances, e.g.: - Battery disconnected. - Plug connections disconnected. - Power failure. In these situations, no fault is present in the system and the fault memory must be erased. Fault memory Info key [F8] In order to be able to assess the fault exactly, the fault memory Info key [F8] must be pressed. This information should be saved using the Save key [F4] and printed out. If a fault code is stored with the status "not present" and no other problems are present, then the fault memory must be erased. Open circuit - short to ground / voltage short / version; vehicle parameters / counter Operating hours The value indicates the operating hours at the time the fault first occurred. Frequency counter When a fault first occurs, a fault entry with the status 'present' is set in the fault memory and the counter is simultaneously set to '50'.

This is a source reference. Confirm exact model applicability in the original material.