Page 2
with a fused shop-made cable. The fuel pump must now operate or deliver fuel.
4.
Nominal test values:
Stationary engine 3.8 ± 0.2 bar
Engine idling 3.3 ± 0.2 bar
NOTE
: The seal or sealing ring in the brass closure cap is
not
exchangeable. It must therefore be used only
once
.
Tightening torque of the new brass closure cap
2.5 ± 0.5 Nm. (2.0 ± 0.5 ftlb.)
.