Page 2 with a fused shop-made cable. The fuel pump must now operate or deliver fuel. 4. Nominal test values: Stationary engine 3.8 ± 0.2 bar Engine idling 3.3 ± 0.2 bar NOTE :  The seal or sealing ring in the brass closure cap is not exchangeable. It must therefore be used only once . Tightening torque of the new brass closure cap 2.5 ± 0.5 Nm. (2.0 ± 0.5 ftlb.) .