Page 2 2. Pump the cooling system up to an excess pressure of 1.3 bar . If the pressure decreases, locate the leak and remedy the fault. Check pressure relief valve(s) in the cap. Screw the tester, adapter and cap together. Test, two-step cap Part number 996 106 447 00 1. Generate excess pressure (step 1) 2. The pressure relief valve opens at an excess pressure of approximately 1.4 bar ; the pressure then slowly decreases again, and the valve closes at 1.0 bar . If the pressure decreases further, replace the cap. 3. If the test pressure of step 1 is maintained, test step 2. Apply excess pressure to the pressure relief valve of step 1 by pumping rapidly. The pressure relief valve of step 2 must open at an excess pressure of approximately 1.8 bar . If the valve does not open, replace the cap.