fullymatted.
Back to search
Workshop Manuals

Instrument Cluster Diagnosis - System K22, K23, K27|Page 96

Add to repair workspace
Open repair workspace
Original source
Page 32 MOST Actual And Required Installed Components Lists All MOST control modules that are connected to the PCM2 are entered via diagnostic tester in the 'required installed components list'. Only the MOST control modules recorded in the MOST required installed components list are activated. An 'actual installed components list' of detected devices is written and saved when the PCM2 is started. MOST Lock/MOST Unlock MOST Lock/MOST Unlock A lock occurs when the signal sent from the MMI via the MOST optical/electrical is understood and answered by the connected MOST control modules. This applies a correct optical MOST signal. The lock is maintained until the signal is no longer detectable for a long period of time (several mue seconds) 'unlock'. NOTE: The 'Reset all coding/transmission counters' function can be used to reset all fault counters that were set for all components to '0'. MOST Switch MOST Switch The MOST switch is part of the PCM2. It keeps the electrical MOST closed if no other MOST control module is optically connected to the MOST. The MOST switch is opened when a light signal is received from the connected MOST control modules. The following settings can be coded: - MOST switch open - MOST switch closed NOTE: - When the PCM2 is replaced, the coding must be performed in accordance with the connected MOST control modules. - When the 'Switch closed' parameter is set, the switch remains closed even in existing MOST control modules. Communication is then not possible. MOST Unlock Counter MOST Unlock Counter Interruptions occur in the system if perfect communication is no longer possible. If the relevant threshold values are exceeded, an entry is recorded in the appropriate control module and the 'unlock counter' is incremented. NOTE: The 'Reset all coding/transmission counters' function can be used to reset all fault counters that were set for all components to '0'. Navigation Navigation The navigation module is designed as a module box, which can be inserted in the PCM2 as an option. Once inserted, an electronic switch is opened automatically and the module is integrated into the MOST ring. PCM2 Control Module (Head Unit) PCM2 Control Module (head Unit) The PCM2 control unit (head unit) includes the following components: Internal: PCM2 gateway PCM2 Man Machine Interface (MMI) Amplifier (internal) Tuner Single CD Navigation (optional/insertion) VOCS (voice control system) (optional/insertion) Controller Area Network (CAN) Comfort MOST switch External:

This is a source reference. Confirm exact model applicability in the original material.