996 Carrera Group 0 Part 1 Diagnosis / PAGE 168

8.1 No communication between diagnostic tester and control module · Test Work instruction Result Possib

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 168
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

911 Carrera 4 (996) PSM diagnosis 8.1 No communication between diagnostic tester and control module Test Work instruction Result Possible causes of fault T01 Test: short to ground in power Greater No: supply circuit than 11 V .Check the following components for correct functioning: .Ignition off battery .All loads switched off and .Pull wiring harness plug off of: generator diagnostic tester .Check following circuits for correct .Measure voltage between the functioning: following terminals: terminal 31 (GP 13) battery wiring harness plug (component and side) terminal 30 terminal 30 and ground Yes:102 102 Test: short to ground/open circuit Greater in power supply circuit than 11 V Check the following componentsforI correct functioning: .Measure voltage betweenthe fuse 81, following terminals: fuse F6i. diagnosiswiring harness plug (wiring Check the following connection pointsI harness side) terminal 16 in the passenger compartmentwiringI!harness: and 17, 120 ground Note: an open circuit or a short circuit is present. Check wiring harnessfor continuityand for pinchesor chafing TO3 damage. 45 -D 105 INo:!.:Yes: