996 Carrera Group 0 Part 1 Diagnosis / PAGE 169
PSM diagnosis 911 Carrera 4 (996) · Test Work instruction Result Possible causes of fa
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
PSM diagnosis 911 Carrera 4 (996)
Test Work instruction Result Possible causes of fault
TO3 Test: open circuit in ground circuit Greater No:
than 11 V -Open circuit between:
.Measure voltage betweenthe diagnosiswiring harness plug terminals
following terminals: 4,5
diagnosis wiring harnessplug (wiring and
harness side) terminal 16 ground point 3.1 (electronics ground)
and
diagnosis wiring harnessplug (wiring
harness side) terminals4, 5 IYes:TO4
T04 component lO.K. No:
-Faulty component
.Check diagnostic tester for correct1!mgiQ diagnostic tester
11(!l g Yes: 105
T05 Test: Short to ground/open circuit Greater No:
in power supply circuit than 11 V .Check the following components for
correct functioning:,fuse
Pull wiring harness plug off of: 89
PSM control module
.Ignition on Note: an open circuit or a short circuit
.Measure voltage between theIfollowing is present. Disconnect the plug
terminals:! connection Xl/3 (terminal 3) for furthertroubleshooting.
PSM control module wiring harness! Check wiring harness
plug (wiring harness side) terminal 1 for continuity and for pinches or chafing
and damage.
Yes: TOG
45 -D 106
Test: