996 Carrera Group 0 Part 1 Diagnosis / PAGE 197
Test Work instruction Result Possible causes of fault · TO3 Test: voltage short / open circuit in Gr
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
Test Work instruction Result Possible causes of fault
TO3 Test: voltage short / open circuit in Greater No:
signal circuit than 11 V -Short circuit to voltage/
open circuit in circuit between:
.Ignition on Relayfor return pump socket terminal 6
.Measure voltage betweenthe and
following terminals: PSMcontrol module
Relayfor return pump socket wiring harness plug (wiring harness side)
terminal 4 terminal 7
and or
relay for return pump socket -PSM control module faulty
terminal 6 104
TO4 Test: short to ground/ Greater No:
open circuit in power supply circuit than 11 V -Short circuit to ground/
open circuit in circuit between:
.Measure voltage between the fuse Fl output-side contact
following terminals: and
Relay for return pump socket terminal 2 relay for return pump socket terminal 2
and
ground Note: The plug connection X 1/3I
(terminal 1) is located in the wiring
harness. Check the wiring harness for
Yes: 105 pinching or chafing damage.
45 -D 134
IYes:I