996 Carrera Group 0 Part 1 Diagnosis / PAGE 198
Test Work instruction Result Possible causes of fault · TO5 open circuit in ground circuit -
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Carrera 4 (996) PSM diagnosis
Test Work instruction Result Possible causes of fault
TO5 open circuit in ground circuit -ess than No:
5 Ohm -open circuit in circuit between:
.Ignition off PSMhydraulic unit
.Pull wiring harness plug off of: wiring harness plug (wiring harness side)
PSM hydraulic unit terminal 13
.Measure resistance betweenthe and
following terminals: ground point 2
PSM hydraulic unit
wiring harnessplug (wiring harness
side)terminal 13
and
ground.. Yes: T06
TOG Test: component Return No:
pump -Open circuit between:
.Connect wiring harness plug to: running Relay for return pump socket terminal 8
PSM hydraulic unit and
.Connect electrically fused wiring hydraulic unit wiring harness plug (wiring
harness jumper to: harness side) terminal 14
Relay for return pump socket terminal 2 orI
and PSM control module faulty
relay for return pump socket terminal 8
Note: Check the wiring harnessfor
Note: Do not let return pump run for pinchingor chafing damage.
longer than 5 seconds!
45 -D 135
Test:J~I91
This is a source reference. Confirm exact model applicability in the original material.