996 Carrera Group 0 Part 1 Diagnosis / PAGE 199

PSM diagnosis 911 Carrera 4 (996) · Test Work instruction Result Possible causes of

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 199
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

PSM diagnosis 911 Carrera 4 (996) Test Work instruction Result Possible causes of fault IrO7 open circuit in signal circuit -ess than No: J Ohm -Open circuit between: Pull wiring harnessplug off of: Relay for return pump socket terminal 8 PSM control module and Measureresistance betweenthe PSM control module following terminals: wiring harness plug (wiring harness side) PSM control module terminal 20 wiring harness plug (wiring harness side) terminal 20 and relay for return pump socket terminal 8 IYes: EO! 1EOl 1-Relayfor return pump faulty I 45 -D 136 IITest: