996 Carrera Group 0 Part 2 Diagnosis / PAGE 62
Test point 1 · Warning light of roll-over This fault is stored in the memory if there is an open circuit or short to
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Carrera (996) Roll-over protection system diagnosis
Test point 1
Warning light of roll-over This fault is stored in the memory if there is an open circuit or short to
protection ground in the supply lead to the warning light in the instrumentcluster.
Open circuit Open circuit
Short to ground
Fault code 1 1. Check bulb and replace if necessary.
2. Check wire to pin 12 for open circuit. Pull plug off the roll-over
protection control module. Pull off plug III on the instrumentcluster.
Measureresistance between plug on roll-over protection control
module pin 12 and plug III on instrumentcluster pin 16
Ohmmeterdisplay: < 5 .Q
Short to ground
Measure resistance between plug on roll-over protection control module
pin 12 and ground
Ohmmeter display: 00.0.
Test point 2
Warning light of roll-over This fault is stored in the memory if there is a short to B+ of the supply
protection lead to the warning light in the instrumentcluster.
Short to B+ 1. Pull off plug on control module and plug III on instrumentcluster.
Fault code 2 Check wire to pin 12 for short to B+.
Switch ignition on. Measurevoltage between plug on roll-over
protection control module pin 12 and ground
Voltmeter display: 0 V
Test point 3
Supplyvoltage This fault is stored in the memory if the supply voltage is insufficient.
Fault code 3 1. Examinebatteryandalternator.
2. Inspectthe plug connectionon the control module for corrosion,
69 71 Diagnosis/troubleshooting, roll-over protection system -UEB11 69 -D 37
Printed in Germany -39, 2000 99669D23
This is a source reference. Confirm exact model applicability in the original material.