996 Carrera Group 0 Part 2 Diagnosis / PAGE 63

Roll-over protection system diagnosis 911 Carrera (996) · Test point 4

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 63
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

Roll-over protection system diagnosis 911 Carrera (996) Test point 4 Solenoidvalves 1 and 2 This fault is stored in the memory if the supply leads of solenoid valves Leakage resistance/short 1 and 2 have a mutual short circuit or leakage resistance. circuit Pull off plugs on control module and on solenoid valves 1 and 2. Check Fault code 4 lines to solenoid valves1 and 2 for shorts to each other. Test point 5 Solenoidvalve 1 This fault is stored in the memory in the event of a short to ground in Short to ground the supply lead of solenoidvalve 1. Fault code 5 Pull off plug on solenoidvalve 1 and plug on control module. 3. Measure resistance between plug on control module pin 4 and ground Display: 00 .Q Measureresistance betweenthe plug on the control module pin 4 and the plug on solenoidvalve 1 pin 2 Display: < 5 .Q Test point 6 Solenoidvalve 1 This fault is stored in the memory if there is an open circuit in the Open circuit supply leads to solenoidvalve 1. Fault code 6 Pull off plug on control module and on solenoid valve 1 Measureresistance between plug on control module pin 4 and plug on solenoid valve 1 pin 2 Display: < 5 .Q Measureresistance betweenthe plug on the control module pin 5 and the plug on solenoidvalve 1 pin 1 Display: < 5 0. Push plug onto solenoidvalve 2 again. Unplugconnector XIO from the subframe. Measureresistance between pins 1 and 2 Ohmmeterdisplay: 4 to 6 0. at 200 C 69 -D 38 69 71 Diagnosis/troubleshooting, roll-over protection system -UEB11 99669D23 Printed in Gemlany -39, 2000

This is a source reference. Confirm exact model applicability in the original material.