996 Carrera Group 0 Part 2 Diagnosis / PAGE 64
Test point 7 · Solenoidvalve 1 This fault is stored in the memory in the event of a short to B+ in the
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Carrera (996) Roll-over protection system diagnosis
Test point 7
Solenoidvalve 1 This fault is stored in the memory in the event of a short to B+ in the
Short to B+ supply lead of solenoidvalve 1 (triggers roll-over bar).
Fault code 7 1. Pull off plugs on control module and on solenoid valves 1 and switch
on the ignition.
Measurevoltage between plug on control module pin 4 and ground
Voltmeter display: 0 V
Test point 8
Solenoidvalve 2 This fault is stored in the event of a short to ground in the lead of
Short to ground solenoidvalve 2.
Fault code 9 Pull off plug on control module and on solenoid valve 2.
Measureresistance between plug on control module pin 17 and ground
Ohmmeterdisplay: 00Q
Push plug onto solenoidvalve 2 again. Unplug connector X10 from the
subframe. Measureresistance between pins 3 and 4
Ohmmeterdisplay: 4 to 6 Q at 200 C
Test point 9
Solenoidvalve 2 This fault is stored in the memory if there is an open circuit in the
Open circuit supply lead to solenoid valve 2.
Fault code 10 1. Pull off plug on control module and on solenoid valve 2
Measure resistance between plug on control module pin 17 and plug
on solenoidvalve 2 pin 2
Ohmmeterdisplay: < 5 Q
2. Measureresistance betweenthe plug on the control module pin 21
and the plug on solenoidvalve 2 pin 1
Ohmmeterdisplay: < 5 .Q
Push plug onto solenoidvalve 2 again. Unplugconnector X10 from
the subframe. Measureresistance between pins 3 and 4
Ohmmeterdisplay: 4 to 6.Q at 200 C
69 71 Diagnosis/troubleshooting, roll-over protection system -UEB11 69 -D 39
Printed in Germany -39, 2000 99669D23