996 Carrera Group 0 Part 2 Diagnosis / PAGE 151

Fault, Fault code Possible causes, elimination, notes · -.- Short to ground

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 151
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

Fault, Fault code Possible causes, elimination, notes -.- Short to ground 1. Unplug connector 8 from the heating/air-conditioningcontrol. 2. Connectohmmeter to connector B 5 and ground Display: 00 .Q If a -5 .0.is displayed,check wiring harnessfor pinching and chafing damage. Test point 5 Supplyvoltage Diagnosis conditions (terminal 15) No controlmodulefaultstored. Voltage too high Voltage too high Voltage too low Fault code 24 Checkthe alternator. Voltage too low 1. Check the alternator. 2. Checkor chargethe battery. 3. Check contact resistance of wire connections. 80 -D 20 80 01 Diagnosis/troubleshooting, heating 99680Dl Printed in Germany -II, 1998

This is a source reference. Confirm exact model applicability in the original material.