996 Carrera Group 0 Part 2 Diagnosis / PAGE 152
Fault, Fault code Possible causes, elimination, notes · Test point 6
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Carrera (996) Heating diagnosis
Fault, Fault code Possible causes, elimination, notes
Test point 6
Supply voltage Diagnosis conditions
(5 volts) No control module fault stored,
Voltage too high Voltage too high
Voltage too low
Fault code 25 1. Unplug connector C from the heating/air-conditioningcontrol.
2. Connectvoltmeterto C 8 andground.
Switchon ignition.
Display: a volts
If the battery voltage is displayed, check the wiring harness
for pinchingand chafing damage.
3. Push on connector C
4. Connectvoltmeter to C 8 and ground.
Switch on ignition.
Display: 5 :i: 0.5 volts
If more than 5.5 volts are displayed,replace the heating/air-conditioning
control.
Voltage too low
1. UnplugconnectorC from the heating/air-conditioningcontrol,
2. Unplugall connectorsfrom the valve drive motors,
3. Connectohmmeter to connector C 8 and ground.
Display: 00 .Q
If 0 -5 .Q is displayed, check wiring harness for pinching
and chafing damage.
8001 Diagnosis/troubleshooting, heating 80 -D 21
Printed in Germany -11, 1998 99680Dl