996 Carrera Group 0 Part 2 Diagnosis / PAGE 156

Test point 9 · Motor of footwell / Diagnosis conditions

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 156
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

911 Carrera (996) Heating diagnosis Test point 9 Motor of footwell / Diagnosis conditions defrost valve No control module fault stored. No fault with supply voltage (5 volts). Signal implausible Fault code 28 Signal implausible 1. Check footwell / defrost valve for smooth operation. 2. Unplug connectorsA, 8, C and D from the heatingjair-conditioning control. 3. Unplugconnector from footwell / defrost valve drive motor. 4. Connectohmmeterto connector C 8 and drive motor connector pin 1. Display: < 5 ,Q Connectohmmeter to connector B 10 and drive motor connector pin 2. Display: < 5 .Q Connectohmmeter to connector A 12 and drive motor connector pin 3, Display: < 5 .0. Connectohmmeter to connector D 11 and drive motor connector pin 4 Display: < 5 .0. Connectohmmeter to connector D 3 and drive motor connector pin 5 Display: < 5 .Q ." 5. Check wire from connector C 8 to drive motor pin 1 for short to B+ and short to ground. 6. Check wire from connector B 10 to drive motor pin 2 for short to B+ and short to ground. 7. Check wire from connector A 12 to drive motor pin 3 for short to B+ 8. Check wire from connector 0 11 to drive motor pin 4 for short to B+ and short to ground. 8 80 01 Diagnosis/troubleshooting, heating 80 -D 25 Printed in Germany -II, 1998 99680Dl -