996 Carrera Group 0 Part 2 Diagnosis / PAGE 157
Heating diagnosis 911 Carrera (996) · Fault, Fault code Possible causes, elimination, notes
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
Heating diagnosis 911 Carrera (996)
Fault, Fault code Possible causes, elimination, notes
9. Check wire from connector D 3 to drive motor pin 5 for short to B+
and short to ground.
Test point 10
Motor of outside air / Diagnosis conditions
recirculation valve No control module fault stored.
No fault with supplyvoltage (5 volts).
Signalimplausible
Fault code 29 Signal implausible
1. Checkoutsideair / recirculationvalvefor smoothoperation.
2. UnplugconnectorsA, 8, C andD from the heatingjair-conditioning
control.
3. Unplugconnectorfrom outsideair / recirculationvalvedrivemotor.
4. Connectohmmeter to connector D 13 and drive motor
connector pin 1.
Display: < 5 .0.
Connectohmmeter to connector D 5 and drive motor connector pin 2,
Display: < 5 Q
Connectohmmeter to connector B 17 and drive motor connector pin 3.
Display: < 5 .Q
Connectohmmeter to connector C 8 and drive motor connector pin 4.
Display: < 5 .Q
Connectohmmeter to connector A 12 and drive motor connector pin 5
Display: < 5 Q
5. Check wire from connector D 13 to drive motor pin 1 for short to B+
and short to ground.
6. Check wire from connector 0 5 to drive motor pin 2 for short to B+
and short to ground.
80 -D 26 8001 Diagnosis/troubleshooting, heating
99680Dl Printed in Germany -11, 1998
This is a source reference. Confirm exact model applicability in the original material.