996 Carrera Group 0 Part 2 Diagnosis / PAGE 176
Load disconnection has a frequency of 10 Hz and indicatestwo · states -normal state (live signal)and
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Carrera (996) Alarm system diagnosis
8
Load disconnection has a frequency of 10 Hz and indicatestwo
states -normal state (live signal)and crash If the vehicle is locked up, some loads are
state. The two states differ in the pulse/duty disconnected from the supply voltage in order
to conserve the battery. Load deactivation is ratio of the signal:
activated if at least one of the following
Live signal 20% high 80% low requirements is fulfilled:
Crashsignal 80%high 20% low 10 minutes after locking up the vehicle via
hand-heldtransmitter or door lock as well as
Signal evaluation begins 45 seconds after term. after re~ocking
S is switched on. If no signal is detected from
the airbag control module, a corresponding fault 2 hours after term. S is switched off
is entered into the fault memory.
2 hours after the central locking system is
Undervoltage unlocked via door lock or hand-held
transmitter If the battery voltage falls below 8.5 V,
undervoltageoccurs. If the battery voltage
2 hoursafter alarmoutput exceeds 9 V, the undervoltageis no longer
present. If undervoltage occurs, the inputs Door
lock barrel open and Door lock barrel closed
are evaluated as inactive irrespective of their
Play prevention state. It is not possible to activate the central
If the central locking system is actuated 11 locking system via the door lock barrel when
times in less than 5 seconds,further operation undervoltageoccurs. The alarm system cannot
is blocked for 30 seconds. If the last command be activated in the case of undervoltage.
before play prevention activation was a
Lid release locking command to open the central locking system,
then it is possible to give a further command Electric locking of the rear lid release has
which is independentfrom play preventionto been omitted as of the production launch of
close the system. For every further time that the '98 series. Front lid release locking is
play prevention is activated the blocking time is still carried out electrically.
doubled, up to a maximum of 240 seconds. The
blocking time is cleared when a door is opened, Electric locking is carried out by the alarm
and if play prevention is activated again, system control module and is valid for the
blocking time starts at 30 seconds. following country codings:
Crash signal USA,Englandand Belgium
The airbag control module emits a signal to the
alarm system control module no later than
35 seconds after Term. S is switched on and
until Term. S is switched off again. This signal
90 -D 9
This is a source reference. Confirm exact model applicability in the original material.
