996 Carrera Group 0 Part 2 Diagnosis / PAGE 177
Alarm system diagnosis 911 Carrera (996) · Load disconnectionis deactivated if at least one the status
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
Alarm system diagnosis 911 Carrera (996)
Load disconnectionis deactivated if at least one the status memory. The same applies if the
of the following requirementsis fulfilled: system is disconnected from the supply voltage
during an alarm output. The alarm output is
Term. S is switched on continued as soon as the necessary supply
voltage is available.
Term. 15 is switchedon
Activating and deactivating alarm system
A valid transponder is recognised The alarm system is activated by a ground
signal at the activation input or by an activation
The vehicle is unlocked or locked via signal from the hand-heldtransmitter.
hand-heldtransmitter or door lock
The activation of the system is ignored if
A door is opened terminal 86 5, terminal 15 or a valid
transponder key is recognised.
Alarm output
If for some reason it is not possible to lock thePower window control
central locking system with a single locking
The control centre not only enables command, the alarm system is not activated.
power-windowcontrol, but also controls the Activation of the alarm system cannot be
comfort functions. If the central locking button achieveduntil the central locking system is
on the hand-heldtransmitter is still pressed after locked (if necessary manually)and a new
an unlocking command has been given, the activation command is issued or only locking is
windows are controlled in the direction open. performed three times in quick succession. The
For a locking command with the central locking interval betweentwo locking operations must
button on the hand-heldtransmitter, if the button not be more than 1 second in this case. If the
is still pressed, the windows are controlled in system is activated by this emergencyfunction,
the direction closed (nationalvariant). the central locking system is locked without
checking whether it can be completelylocked.
Power-on behaviour
After the operating voltage is switched on, the
system is set to the operating state which it
was in before the supply voltage was switched
off.
For this purpose, all necessary operating
parameters are stored in a permanentmemory.
If the system was disconnected from the supply
in the armed state, this is entered as a fault in
9001
This is a source reference. Confirm exact model applicability in the original material.
