996 Carrera Group 0 Part 2 Diagnosis / PAGE 180
Function display and audible checkback · The operating state of the central locking LEDflashes with a frequency of 0.5
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
Function display and audible checkback
The operating state of the central locking LEDflashes with a frequency of 0.5 Hz
system is fed back via the output "Door locked" On time 1,2 = 100 ms
and by corresponding activation of the interior Off time 1 = 200 ms
light (signals 1 to 3). The operating state of Off time 2 = 1700 ms
the alarm system is also indicated during
the inactive period by the alarm readiness DisDla~ ~De 3 (raQid flashing)
display (displaytypes 1 to 6) and exclusively
by the alarm readiness displayfollowing expiry Requirement: alarm system primed
no active alarm inputsof the inactive period. Displayedsystem faults
are always current faults. Previoussystem Duration: inactiveperiod,faults entered in the status memory have then displaytype 1
no influenceon the function display.
LEDflashes with a frequency of 2 Hz
Displa~~pe 1 (normal flashing) On time = lOOms
Off time = 400 msRequirement: Alarm system primed
no alarm output or Displa~~pe 4 (rapid flashing)
no active alarm input
after re-iocking if Requirement: Reception of an adapted
no alarm input is active handheldtransmitter
Duration: until deactivation, Duration: push of the button
then Displaytype 6
LED flashes with a frequency of 10 Hz
LEDflasheswith a frequencyof 0.5 Hz On time = 50 ms
On time = lOOms Off time = 50 ms
Offtime = 1900 ms
DisRla~~Re 5 (on)
DisQla~ ~Qe 2 (double flashing)
Requirement: after central locking
Requirement: after alarm output or system emergency
active alarm input locking or after locking
after activation command is given twice
or re-locking via handheldtransmitter
or door lock
Duration: until deactivation,
then Displaytype 6 Duration: in the case of central
locking system emergency
locking, inactive period
then displaytype 2
in the case of locking
command given twice,
inactive period
then displaytype 1
The LED is continuouslyon