996 Carrera Group 0 Part 2 Diagnosis / PAGE 195
Alarm system diagnosis 911 Carrera (996) · Test point 1
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
Alarm system diagnosis 911 Carrera (996)
Test point 1
Door(s)secured and 1. Disconnectplug connection X 11 (driver's side).
terminal 15 on 2. Check the lead from X 11 pin Al (pin side)to the alarm control
Fault code 01 module plug I, pin 5, for continuity.
3. Check the leads from X 11 pin Al and pin 26 (sleeve side) for
continuity.
Note
There is another plug connection in the door on the door lock module.
4. Disconnectthe plug connection X 12 (passenger'sside).
5. Check the lead from X 12 pin Al (pin side)to the alarm control
module plug I, pin 28, for continuity.
6. Check the leads from X 12 pin Al and pin 26 (sleeve side)for
continuity.
Test point 2
Door lock barrel closed, Note
activated longer than 60 s This fault can also be caused by incorrect operation (door lock
Fault code 02 actuated toward "Closed"direction for longer than 60 seconds).
1. Pull off plug I on the alarmcontrolmodule.
2. Disconnectplug connection X 11 (driver's side).
3. Disconnectthe plug connectionX 12 (passenger'sside),
This is a source reference. Confirm exact model applicability in the original material.