996 Carrera Group 0 Part 2 Diagnosis / PAGE 196
4. Check the leads from the alarm control module plug I pin 35 to the · door lock modules for short to ground.
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Carrera (996) Alarm system diagnosis
4. Check the leads from the alarm control module plug I pin 35 to the
door lock modules for short to ground.
Ohmmeter on alarm control module plug I pin 35 and ground.
Display: 00Q
5. Checkdriver'ssidedoor lock moduleswitchcontact.
Ohmmeter at plug connection X 11 pin A2 (sleeve side) and ground
Door lock not actuated.
Display: 00.0.
Door lock actuated towards "Closed",
Display: < 5 .Q
6. Check passenger'sside door lock module switch contact.
Ohmmeter at plug connection X 12 pin A2 (sleeve side) and ground.
Door lock not actuated.
Display: 00.Q
Door lock actuated towards "Closed",
Display: < 5 .Q
Test point 3
Door lock barrel open, Note
actuated for longer than 60 5 This fault can also be caused by incorrect operation (door lock
Fault code 03 actuated toward "Open"direction for longer than 60 seconds).
1. Pull off plug I on the alarm control module.
2. Disconnect plug connection X 11 (driver's side).
3. Disconnectthe plug connection X 12 (passenger'sside).
4. Check the leads from the alarm control module plug I pin 15 to the
door lock modules for short to ground.
90 -D 29
This is a source reference. Confirm exact model applicability in the original material.