996 Carrera Group 0 Part 2 Diagnosis / PAGE 205
Fault, Fault code Possible causes, elimination, notes · Test point 20
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
Fault, Fault code Possible causes, elimination, notes
Test point 20
Status lead, 1. Pull off plug I on the alarm control module.
signal converter 2. Pull off the plug on the signal converter for the transponder.
Short to ground
Fault code 20 3. Ohmmeter on alarm control module plug I pin 12 and ground.
Display: 00.0.
If display < 5 .0.,check wiring harnessfor chafing and pinching
damage.
Test point 21
W-iead(DME - 1. Pull off plug I on the alarm control module.
immobilizer) 2. Unplugthe DME (ECM)connector.
Open circuit
Fault code 21 3. Ohmmeter at plug I, alarm control module pin 23, and
DME plug pin 88.
Display: < 5 Q
Note
The lead is routed via plug connection X 3/1 pin 14.
4. Ohmmeter on alarm control module plug I pin 23 and ground.
Display: 00.Q
5. Voltmeter at plug I alarm control module pin 23 and ground,
Switch ignition on.
Display:a Volt
If no fault can be detected in the wires, either the DME control
module or the alarm system control module is faulty.
90 -D 38 9001 Diagnosis/troubleshooting, alarm system two-motor lock