996 Carrera Group 0 Part 2 Diagnosis / PAGE 206
Fault, Fault code Possible causes, elimination, Notes · Test point 22
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Carrera (996) Alarm system diagnosis
Fault, Fault code Possible causes, elimination, Notes
Test point 22
Passenger compartment 1. Pull off plug I on the alarm control module.
monitoring sensor 2. Pull off the plug at the passenger compartment monitoring sensor.
Short to ground
Fault code 22 3. Ohmmeteron alarm control module plug I pin 24 and ground.
Display: 00.0.
If display < 5 .0.,check wiring harnessfor chafing and pinching
damage.
Test point 23
W-iead See test point 21, point 5,
(DME-immobilizer)
Short to B+
Fault code 23
Test point 24
Control module faulty Replacecontrol module.
Fault code 24
Test point 25
No terminal 86 S 1. Checkthe fuse F 5/1.
recognised 2. Pulloff plug I on the alarmcontrolmodule.
Fault code 25
3. Volbneter at plug I alarm control module pin 16 and ground.
Insert the ignition key into the ignitionlock.
Display: Battery voltage
4. Pull off the plug on the ignition lock.
5. Ohmmeter at ignition lock plug pin 86 S and plug I, alarm
control module pin 16.
Display: < 5 .Q
6. If no fault is detected, replace the electrical contact part
of the ignition lock.
This is a source reference. Confirm exact model applicability in the original material.