Group 0 · General / PAGE 240
Transmission 9113 · 10 – Speed sensor 12 – Starter interlock contact
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
Transmission 9113
10 – Speed sensor 12 – Starter interlock contact
11 – Speed sensor 13 – Temperature sensor
Transmission ratio and shifting components
Gear Trans. B1 B2 B3 K1 K2 K3 F1 F2
ratio
1 3.60 X 3) X X 3) X X
2 2.19 X X X 3) X
3 1.41 X X X
4 1 X X X
5 0.83 X 3) X X X
N -- X X
R (1) 3.17 X 3) X X X
R (2) 1.93 X X X
1) = Reverse gear transmission ratio, standard
2) = Reverse gear transmission ratio, reduced torque
3) = Shifting components only actuated in overrun mode
3 889 S o leno id valves
The solenoid valves are 3/2-way valves and
are actuated by the Tiptronic control unit to
initiate upshifts and downshifts. If a solenoid
valve is actuated, it opens and directs control
pressure to the assigned command slide
valve. The solenoid valve remains actuated
and therefore open until the shifting opera-
tion has been completed. If the solenoid valve
is de-energised, the pressure along the con-
trol line to the command slide valve is re-
duced to zero.
Two O-rings (1 and 2) form the seal between
the solenoid valves and the control plate. The
valves are pressed against the control plate
(4) by flat springs (3). The contact springs (5)
on the solenoid valve engage in a slot in the
conductors (6). The spring force ensures reli-
able contacting.
3_04_00
3 - 14 Service Information 2002
This is a source reference. Confirm exact model applicability in the original material.