87 Nominal values for pressures and temperatures
Note
The temperature of the air from the "centre"dashboardvents must lie within the prescribed tolerance
range within 5 minutes, dependingon the ambienttemperature (see diagram),
General test prerequisites
Close doors, windows and sliding roof
Insert temperature probe into centre vent
Measure ambienttemprature
Open all dashboardvents
Switch ignition on
Press recirculating-airbutton
Set temperature control to maximum cooling
Switch fresh-air blower to stage 4
Start engine
Operate air condition while idling
Set engine speed to 2000 rpm (start of time measurement)
If the prescribed nominal values are not reached,the cooling system must be checked for leaks and
repaired.
10
u0
.5 8
aJ'-~+-'
ro'-
a.aJ
E 6
.$
aJ
N
N
0 4
C
+-'aJ'-
C
aJ
U 2
15 20 25 30 35 40
Outside temperature in °C 569/1 .96
Centre vent temperature as a function of ambienttemperature
87 Nominal values for pressures and temperatures 87 -13