87 Nominal values for pressures and temperatures · The temperature of the air from the "centre"dashboardvents must lie wi

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 33
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

87 Nominal values for pressures and temperatures Note The temperature of the air from the "centre"dashboardvents must lie within the prescribed tolerance range within 5 minutes, dependingon the ambienttemperature (see diagram), General test prerequisites Close doors, windows and sliding roof Insert temperature probe into centre vent Measure ambienttemprature Open all dashboardvents Switch ignition on Press recirculating-airbutton Set temperature control to maximum cooling Switch fresh-air blower to stage 4 Start engine Operate air condition while idling Set engine speed to 2000 rpm (start of time measurement) If the prescribed nominal values are not reached,the cooling system must be checked for leaks and repaired. 10 u0 .5 8 aJ'-~+-' ro'- a.aJ E 6 .$ aJ N N 0 4 C +-'aJ'- C aJ U 2 15 20 25 30 35 40 Outside temperature in °C 569/1 .96 Centre vent temperature as a function of ambienttemperature 87 Nominal values for pressures and temperatures 87 -13 Printed in Germany, 1997 9968713