Group 9 · Electrics / PAGE 34

Air conditioning 911 Carrera (996) · Nominal values for pressures and temperatures

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 34
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

Air conditioning 911 Carrera (996) Nominal values for pressures and temperatures 30 25 "-~ 20 .Q .~ C1) 15 "- ~ II> II>C1)"- 10 Co~ :i: 5 15 20 25 30 35 40 Outside temperature in °C 570/1 -96 Highpressurein cold circuitas a functionof ambienttemperature 1,8 1,7 1,6 '-ro .Q .5 1,5 Q)'-~ (/) (/) 1,4 Q)'- Co :s: 0 .-J 1,3 15 20 25 30 35 40 Outside temperature in °C 571'1 -96 Low pressure in cold circuit as a function of ambienttemperature 87 -14 87 Nominal values for pressures and temperatures 9968713 Printed in Germany, 1997 ~~~~~~:::::;~~~~~~:::::~~~::::::