Single Row Pro IMS Retrofit Installation Manual — LN Engineering / PAGE 12
At this point, installer has a choice of the conventional method using the IMS Pro Tool Kit OR the optional method · using the Fau
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
At this point, installer has a choice of the conventional method using the IMS Pro Tool Kit OR the optional method
using the Faultless IMS Tool to extract the original bearing. Depending on the method you have chosen, please
follow the steps as marked accordingly: IMS Pro Tool Kit OR Faultless IMS Tool
STEPS 16.1 through 16.3 STEPS 16.4 through 16.9
All threaded, thrust, and friction surfaces must be lubricated to ensure long life of your tools.
The O.D. Threaded tube that screws into the mounting plate of the Faultless IMS Tool will be referred to herein as the bearing puller tube,
however it is also used to install the new bearing.
NOTE
INSTALLATIONINSTALLATIONMANUALMANUAL PAGE 9