Single Row Pro IMS Retrofit Installation Manual — LN Engineering / PAGE 13
Bearing extraction - conventional method only! Using IMS Pro Tool Kit. · STEP STE
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
Bearing extraction - conventional method only! Using IMS Pro Tool Kit.
STEP STEP
16.1 16.2
Slide puller body of threaded rod. Install puller Using IMS Pro Tool Kit puller, extract bearing from
washer and nut onto puller and lubricate. intermediate shaft.
Hold threaded rod still while tightening nut on puller to extract
bearing from intermediate shaft. Once bearing is extracted,
thoroughly clean the inside of the intermediate shaft using a
NOTE lint-free cloth.
Watch for an oil release when the IMS Bearing is extracted.
TIP
INSTALLATIONINSTALLATIONMANUALMANUAL PAGE 10