Single Row Pro IMS Retrofit Installation Manual — LN Engineering / PAGE 24

Adjust threaded rod so to ensure it is making contact with the thrust bearing/bearing driver and that the · bearing driver is also

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 24
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

STEP 24 Adjust threaded rod so to ensure it is making contact with the thrust bearing/bearing driver and that the bearing driver is also in contact with the outer race of the new bearing so everything in the assembly is pre-loaded. INSTALLATIONINSTALLATIONMANUALMANUAL PAGE 21