Single Row Pro IMS Retrofit Installation Manual — LN Engineering / PAGE 25

STEP STEP · 25 26

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 25
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

STEP STEP 25 26 Screw bearing puller tube assembly onto mounting plate You are now ready to push the new bearing into the firmly until contact is made with the shaft. Check if intermediate shaft. Holding the smaller inner nut bearing puller tube is snugged up against the with an open-ended box wrench, turn the outer nut intermediate shaft before tightening the lock collar clockwise to press the new bearing into the using a screwdriver. intermediate shaft housing. There might be an audible indicator that the wire lock has seated in the intermediate shaft, however it is up to the installer to judge whether the bearing is fully seated without NOTE applying excessive torque. INSTALLATIONINSTALLATIONMANUALMANUAL PAGE 22