Group 9 · Electrics / PAGE 63
Air conditioning 911 Carrera (996) · Running-in regulations for new compressor
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
Air conditioning 911 Carrera (996)
Running-in regulations for new compressor
Note
Fill the air-conditioningsystem (fluid)via the
high-pressureside from the refrigerant circuit
with the engine "OFF",
1. If possible, all air outlet nozzles "OPEN",
circulating air "CLOSED".
2. Start the engine and allow idle speed to
stabilize (approx. 5 seconds).
3. Set the fan to max. output.
4. Switch on the air-conditioningsystem
(AG switch) and allow it to run uninterrupted
for at least 2 minutes at 1500 rpm.
5. After 2 minutes uninterrupted compressor
operationtime, the oil distribution in the
air-conditioningsystem is completed and
the compress~r can be run up to the
max. engine speed.
87 -54 87 34 19 Removing and installing compressor -GT3
GT38751 Printed in Germany -25, 1999.
This is a source reference. Confirm exact model applicability in the original material.