fullymatted.
Back to search
996 Turbo diagnostic manual — Turbo applicability only / PAGE 376

80-10Fault code 24 · Supply voltage (terminal 15) - voltage too high/ too

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 376
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

911 Turbo (996) Air conditioning H01, H02 80 80-10Fault code 24 Supply voltage (terminal 15) - voltage too high/ too low Diagnostic conditions • Ignition on Note! No control module fault stored Possible cause of fault ♦Low battery positive voltage ♦Generator faulty Affected terminals Plug D, terminals 9 and 15 Diagnosis/troubleshooting Work instruction Display OK If not OK 1 Check battery. ⇒ Step 2 Charge or replace battery → End 2 Check the generator. ♦Check generator voltage ⇒ Step 3 Replace generator approx. 13 to 14 V when engine → End is running. 3 Check contact resistance ♦Switch off ignition Battery voltage Check wiring har- of wire connections. → End ness for fuse E7. ♦Remove plug D from the air-con- Check wiring har- ditioning system regulator ness for ground ♦Switch on ignition point 4. ♦Measure voltage between plug → End D, air-conditioning system regu- lator pin 9 and ground ♦Measure voltage between plug D, air-conditioning system regu- lator pin 7 and ground ♦Measure voltage between plug D, air-conditioning system regu- lator pin 9 and pin 15 8001 Fault code 24 80-10 page 1 Printed in Germany – 15, 2001 24xxxh02

This is a source reference. Confirm exact model applicability in the original material.