996 Turbo diagnostic manual — Turbo applicability only / PAGE 378

Air conditioning H01, H02 911 Turbo (996)80 · Work instruction Disp

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 378
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

Air conditioning H01, H02 911 Turbo (996)80 Work instruction Display OK If not OK 3 Check 5 V supply line for ♦Switch off ignition ∞ Ω Repair wiring har- short to ground ⇒ Step 3 ness ♦Remove plug B from the air-con- → End ditioning system regulator ♦Disconnect plugs from all flap motors ♦Measure resistance at plug B of the air-conditioning system regu- lator between pin 20 and ground 4 Check potentiometer in ♦Measure resistance between 4 - 5 kΩ Replace motor for the temperature mixing pins 1 and 3 of temperature mix- ⇒ Step 5 temperature mixing valve. ing valve valve. → End 5 Check potentiometer in ♦Measure resistance between 4 - 5 kΩ Replace motor for the footwell defrost flap pins 1 and pin 3 of footwell ⇒ Step 6 footwell defrost flap. defrost flap → End 6 Check potentiometer in ♦Measure resistance between 4 - 5 kΩ Repace motor for the central flap. pins 1 and 3 of the central flap Step 7 temperature mixing valve. → End 7 Check potentiometer in ♦Measure resistance between 4 - 5 kΩ Replace motor for der outside air / recircula- pins 4 and 5 of the outside air / Step 8 temperature mixing tion valve recirculation air valve valve. → End 8 ♦Replace air-conditioning system regulator → End 80-11 page 2 8001 Fault code 25 25xxxh02 Printed in Germany – 15, 2001

This is a source reference. Confirm exact model applicability in the original material.