996 Turbo diagnostic manual — Turbo applicability only / PAGE 381
Work instruction Display OK If not OK · 6 Check 5 V supply lead ♦R
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Turbo (996) Air conditioning H01, H02 80
Work instruction Display OK If not OK
6 Check 5 V supply lead ♦Remove plug B from the air- 0 V Repair wiring har-
for short to B+ conditioning system regulator ⇒ Step 7 ness
→ End ♦Switch on ignition
♦Measure voltage at plug B of
the air-conditioning system reg-
ulator between pin 20 and
ground
7 Check 5 V supply line for ♦Measure resistance at plug B ∞ Ω Repair wiring har-
short to ground of the air-conditioning system ⇒ Step 8 ness
regulator between pin 20 and → End
ground
8 Check 5 V supply line ♦Measure resistance between < 5Ω Repair wiring har-
and ground line for open plug B on the air-conditioning ⇒ Step 9 ness
circuit system regulator pin 20 and → End
plug on temperature mixing
valve pin 3
♦Measure resistance between
plug B on the air-conditioning
system regulator pin 9 and
plug on temperature mixing
valve pin 1
9 Check ground line for ♦Measure resistance between < 5Ω Repair wiring har-
open circuit plug B on the air-conditioning ⇒ Step 11 ness
system regulator pin 9 and → End
plug on temperature mixing
valve pin 1
10 ♦Repace servo motor for temperature mixing valve → End
11 ♦Replace air-conditioning system regulator → End
8001 Fault code 26 80-12 page 3
Printed in Germany – 15, 2001 26xxxh02