996 Turbo diagnostic manual — Turbo applicability only / PAGE 382

80-13Fault code 27 · Central flap motor - No reaction to activation, signal

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 382
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

911 Turbo (996) Air conditioning H01, H02 80 80-13Fault code 27 Central flap motor - No reaction to activation, signal unclear Diagnostic conditions • Ignition on Note! ♦No control module fault stored ♦No fault with supply voltage (5 V) Possible cause of fault ♦Short circuit to voltage/ground or open circuit in the wiring between the air-conditioning system regulator and the central flap ♦Servo motor for central flap faulty or flap does not open/close smoothly. Affected terminals Plug B, terminals 9, 14 and 20 Plug D, terminals 4 and 12 Diagnosis/troubleshooting Work instruction Display OK If not OK 1 Visual inspection ♦Switch off ignition Check the connec- Clean connector or tor for corrosion plug in correctly ♦Remove the connector for the and that it is cor- → End central flap rectly inserted ⇒ Step 2 2 Check 5 V - supply line to ♦Switch on ignition approx. 5 V ⇒ Step 6 central flap motor ⇒ Step 3 ♦Measure voltage at plug of the central flap between pin 3 and ground ♦Measure voltage at plug of the central flap between pin 3 and pin 1 8001 Fault code 27 80-13 page 1 Printed in Germany – 15, 2001 27xxxh02

This is a source reference. Confirm exact model applicability in the original material.