996 Turbo diagnostic manual — Turbo applicability only / PAGE 382
80-13Fault code 27 · Central flap motor - No reaction to activation, signal
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Turbo (996) Air conditioning H01, H02 80
80-13Fault code 27
Central flap motor - No reaction to activation, signal
unclear
Diagnostic conditions
• Ignition on
Note!
♦No control module fault stored
♦No fault with supply voltage (5 V)
Possible cause of fault
♦Short circuit to voltage/ground or open circuit in the wiring
between the air-conditioning system regulator and the central
flap
♦Servo motor for central flap faulty or flap does not open/close
smoothly.
Affected terminals
Plug B, terminals 9, 14 and 20
Plug D, terminals 4 and 12
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Visual inspection ♦Switch off ignition Check the connec- Clean connector or
tor for corrosion plug in correctly ♦Remove the connector for the
and that it is cor- → End central flap
rectly inserted
⇒ Step 2
2 Check 5 V - supply line to ♦Switch on ignition approx. 5 V ⇒ Step 6
central flap motor ⇒ Step 3 ♦Measure voltage at plug of the
central flap between pin 3 and
ground
♦Measure voltage at plug of the
central flap between pin 3 and
pin 1
8001 Fault code 27 80-13 page 1
Printed in Germany – 15, 2001 27xxxh02
This is a source reference. Confirm exact model applicability in the original material.