996 Turbo diagnostic manual — Turbo applicability only / PAGE 384

Work instruction Display OK If not OK · 6 Check 5 V supply lead ♦R

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 384
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

911 Turbo (996) Air conditioning H01, H02 80 Work instruction Display OK If not OK 6 Check 5 V supply lead ♦Remove plug B from the air- 0 V Repair wiring har- for short to B+ conditioning system regulator ⇒ Step 7 ness → End ♦Switch on ignition ♦Measure voltage at plug B of the air-conditioning system reg- ulator between pin 20 and ground 7 Check 5 V supply line for ♦Measure resistance at plug B ∞ Ω Repair wiring har- short to ground of the air-conditioning system ⇒ Step 8 ness regulator between pin 20 and → End ground 8 Check 5 V supply line ♦Measure resistance between < 5Ω Repair wiring har- and ground line for open plug B on the air-conditioning ⇒ Step 9 ness circuit system regulator pin 20 and → End plug on central flap pin 3 ♦Measure resistance between plug B on the air-conditioning system regulator pin 9 and plug on central flap pin 1 9 Check ground line for ♦Measure resistance between < 5Ω Repair wiring har- open circuit plug of air-conditioning system ⇒ Step 11 ness regulator Pin B9 and plug of → End central flap pin 3 10 ♦Servo motor for central flap → End 11 ♦Replace air-conditioning system regulator → End 8001 Fault code 27 80-13 page 3 Printed in Germany – 15, 2001 27xxxh02